1003233.1 Flame-Resistant (FR) Jackets
Click here for a PDF of this Material Standard
Revision 1
Sep 28, 2016
1. Scope
This material standard covers the general requirements for manufacturing and supplying all of the District's Flame-Resistant (FR) Jackets.
2. Reference Standards
Where applicable and unless otherwise stated in this specification, garments shall comply with the latest revision of District Material Standard FRCLOTHMAT.
3. FR Insulated Work Jacket
3.1 Material
All materials used shall meet NFPA 70E standard, latest revision. All thread used shall be FR rated. All closures, zippers, tapes, draw cords, snaps and buttons used shall be FR rated and arc-resistant.
3.2 Construction
Insulated Work Jacket shall be constructed in a heavy duty, work coat style. Insulated Work Coats shall be designed to accommodate a removable hood.
3.3 Ratings
Insulated Work Jacket shall have a minimum rating of HRC-4 and an Arc Thermal Performance Value (ATPV) of at least 54 cal/cm².
3.4 District Catalog Identification Numbers
The requirements above correspond to the following District Material Master ID's:
5000552 FR JACKET INSULATED WORK
4. FR INSULATED BOMBER JACKET
4.1 Material
All materials used shall meet NFPA 70E standard, latest revision. All thread used shall be FR rated. Fabric shall be wind/water resistant. All closures, zippers, tapes, draw cords, snaps and buttons used shall be FR rated and arc-resistant.
4.2 Construction
Insulated Bomber Jackets shall be constructed in a heavy duty, bomber jacket style. Insulated Bomber Jackets shall be designed to accommodate a removable hood.
4.3 Ratings
Insulated Bomber Jackets shall have a minimum rating of HRC-3 and an Arc Thermal Performance Value (ATPV) of at least 34 cal/cm².
4.4 District Catalog Identification Numbers
The requirements above correspond to the following District Material Master ID's:
5000553 FR JACKET INSULATED BOMBER
5. FR SHELL JACKET
5.1 Material
All materials used shall meet NFPA 70E standard, latest revision. All thread used shall be FR rated. Fabric shall be wind/water resistant. All closures, zippers, tapes, draw cords, snaps and buttons used shall be FR rated and arc resistant.
5.2 Construction
Shell Jackets shall be designed to accommodate a removable hood.
5.3 Ratings
Shell Jackets shall have a minimum rating of HRC-3 and an Arc Thermal Performance Value (ATPV) of at least 26.3 cal/cm².
5.4 District Catalog Identification Numbers
The requirements above correspond to the following District Material Master ID's:
5000554 FR JACKET SHELL
6. FR Soft-Shell Jacket
6.1 Material
All materials used shall meet NFPA 70E standard, latest revision. All thread used shall be FR rated. Fabric shall be wind/water resistant. All closures, zippers, tapes, draw cords, snaps and buttons used shall be FR rated and arc resistant.
6.2 Construction
Soft-Shell Jackets shall be designed to accommodate a removable hood.
6.3 Ratings
Soft-Shell Jackets shall have a minimum rating of HRC-2 and an Arc Thermal Performance Value (ATPV) of at least 17.9 cal/cm².
6.4 District Catalog Identification Numbers
The requirements above correspond to the following District Material Master ID's:
5000555 FR JACKET SOFT-SHELL
7. FR Fleece Jacket
7.1 Material
All materials used shall meet NFPA 70E standard, latest revision. All thread used shall be FR rated. Fabric shall be lightweight, wind resistant and retain body heat. All closures, zippers, tapes, draw cords, snaps and buttons used shall be FR rated and arc-resistant.
7.2 Construction
Fleece Jackets shall have full zip front. Shoulders and forearms shall have reinforced rip-stop fabric.
Fleece Jackets shall have armpit ventilation for body temperature control. Fleece Jackets shall have drop-tail rear hem and longer sleeves for extra coverage when reaching.
7.3 Ratings
Fleece Jackets shall have a minimum rating of HRC-2 and an Arc Thermal Performance Value (ATPV) of at least 17.9 cal/cm².
7.4 District Catalog Identification Numbers
The requirements above correspond to the following District Material Master ID's:
5000556 FR JACKET FLEECE
8. FR Flack Jacket
8.1 Material
All materials used shall meet NFPA 70E standard, latest revision. All thread used shall be FR rated. Fabric shall be wind/water resistant. All closures, zippers, tapes, draw cords, snaps and buttons used shall be FR rated and arc resistant.
8.2 Construction
Flack Jackets shall have full zip front with hood designed for wear under hardhats. Fabric used shall provide stretch for freedom of movement. Flack Jackets shall have a drop-tail rear hem and extra-long sleeves to provide additional coverage when reaching. Flack Jackets shall have durable fabric strategically placed in high wear areas for durability.
8.3 Ratings
Flack Jackets shall have a minimum rating of HRC-2 and an Arc Thermal Performance Value (ATPV) of at least 16 cal/cm².
8.4 District Catalog Identification Numbers
The requirements above correspond to the following District Material Master ID's:
5000557 FR JACKET FLACK
9. FR Stretch Jacket
9.1 Material
All materials used shall meet NFPA 70E standard, latest revision. All thread used shall be FR rated. Fabric shall be highly breathable and wickable to keep skin dry. All closures, zippers, tapes, draw cords, snaps and buttons used shall be FR rated and arc-resistant.
9.2 Construction
Stretch Jackets shall have full-zip front. Fabric used shall provide stretch for freedom of movement. Stretch Jackets shall have an extended inseam construction that improves range of motion.
9.3 Ratings
Stretch Jackets shall have a minimum rating of HRC-2 and an Arc Thermal Performance Value (ATPV) of at least 15 cal/cm².
9.4 District Catalog Identification Numbers
The requirements above correspond to the following District Material Master ID's:
5000558 FR JACKET STRETCH